V3
max height m 10,25
Suitable for heavy duty
Three-section push-up and A frame fiberglass ladder
Three-section ladder equipped with base stabiliser and sliding wall.
When used as a stepladder, the third section is only used as a guardrail.
Professional fiberglass ladders suitable for those operators who work next to cables, outlets or other electric energy sources.
The fiberglass frames assure electric insulation but our ladders are also light and easy to manage thanks to the non-skid knurled aluminium rungs.
TECHNICAL FEATURES
• Step distance 28 cm
• Rungs section 27x27 mm
• Capacity 150 kg
• No. of rungs: 8 to 14
• Stepladder height: m 2,30 to m 4,00
• Height leant to a wall: m 4,93 a m 10,25
• Base section width cm 49
• Intermediate section width cm 42
• Final section width cm 36
STANDARD PARTS
• Base stabiliser
• Adjustable wrench for stabiliser fastening
• Nylon reinforcement inside stabiliser seat
• Strap preventing uncontrolled ladder opening
• Sliding wheels
• Aluminium opening system
• Non-skid rubber feet
• Device to stop upward movement
• Extension blocking device
• Label and instructions for assembly and use
Available also with rope to be used only leant to wall.
Very important: this model can¬not be used as a stepladder
When used as a stepladder, the third section is only used as a guardrail.
Professional fiberglass ladders suitable for those operators who work next to cables, outlets or other electric energy sources.
The fiberglass frames assure electric insulation but our ladders are also light and easy to manage thanks to the non-skid knurled aluminium rungs.
TECHNICAL FEATURES
• Step distance 28 cm
• Rungs section 27x27 mm
• Capacity 150 kg
• No. of rungs: 8 to 14
• Stepladder height: m 2,30 to m 4,00
• Height leant to a wall: m 4,93 a m 10,25
• Base section width cm 49
• Intermediate section width cm 42
• Final section width cm 36
STANDARD PARTS
• Base stabiliser
• Adjustable wrench for stabiliser fastening
• Nylon reinforcement inside stabiliser seat
• Strap preventing uncontrolled ladder opening
• Sliding wheels
• Aluminium opening system
• Non-skid rubber feet
• Device to stop upward movement
• Extension blocking device
• Label and instructions for assembly and use
Available also with rope to be used only leant to wall.
Very important: this model can¬not be used as a stepladder
EUROPEAN STANDARD CEI EN 50528:
The V3 fiberglass ladder complies with Standard EN 50528 which concerns ladders used for work on low voltage live parts such as making connections, work on supports and switching operations.
These ladders are also used for preliminary operations for live work such as checking the voltage, earthing and short-circuiting, etc.
The purpose of this Standard is to provide ladders that have two main functions: access to the parts of the system on which work must be done and protect the worker from electrical risks by providing the level of insulation and maintaining a safety distance between the operator and the potentially live parts of the system.
It concerns insulating ladders for use on low voltage systems or in their proximity.
This Standard, which complies with EN 61477, must be used in accordance with Standards EN 50110-1 and EN 50110-2.
This Standard is published by CEI in English only as it is particularly aimed at specialized sectors.
This Standard remains applicable until 29-04-2027.
The tests are carried out with an electric charge of 36,000 Volts for one minute.
These ladders are also used for preliminary operations for live work such as checking the voltage, earthing and short-circuiting, etc.
The purpose of this Standard is to provide ladders that have two main functions: access to the parts of the system on which work must be done and protect the worker from electrical risks by providing the level of insulation and maintaining a safety distance between the operator and the potentially live parts of the system.
It concerns insulating ladders for use on low voltage systems or in their proximity.
This Standard, which complies with EN 61477, must be used in accordance with Standards EN 50110-1 and EN 50110-2.
This Standard is published by CEI in English only as it is particularly aimed at specialized sectors.
This Standard remains applicable until 29-04-2027.
The tests are carried out with an electric charge of 36,000 Volts for one minute.